Ogden rules
Last verified November 17, 2026.
Current law is City Code 15-13-39. Email from Ogden City Planning, November 16, 2026, confirmed that section is current and that the Zone Ogden update is unscheduled. Height and setbacks below are the accessory-building rules in 15-13-33 and the zone chapters, applied as Planning described.
An ADU is allowed in all residential zones. Only one ADU is allowed, and only on a parcel with a single-family home. It is not allowed in a PRUD, apartment, group dwelling, or condominium (15-13-39).
Current law also excludes part of the R-1 zones (15-15-2, Ordinance 2024-12): Harrison Boulevard to Polk Avenue between 26th Street and the north side of 35th Street, and Polk Avenue to the eastern city limits between 26th Street and the lots on 36th Street. This Mount Ogden exclusion may conflict with the state detached-ADU rule for lots of 11,000 square feet or more. That is a flag, not legal advice.
No lot minimum is stated. A detached ADU is 300 to 800 square feet and no more than 25 percent of the rear-yard area. It must match the design of the main building.
Accessory-building height is the lesser of 25 feet or 80 percent of the main building’s highest point. If that highest point is 16 feet or less, the limit is 12.5 feet.
Setbacks follow the parcel’s zone accessory-building standards. Planning said to confirm them for the specific parcel. Interior side, interior rear, and corner street side, in feet: R-1-10 is 10 or 1, 1 or 10, and 20 (average minimum 15). R-1-8 is 8 or 1, 1 or 8, and 20 (15). R-1-6 is 8 or 1, 1 or 8, and 20 (15). R-1-5 is 5 or 1, 1 or 6, and 20 (15). R-2 is 8 or 1, 1 or 8, and 20 (15). R-2A is 6 or 1, 1 or 6, and two front yards of 25 (20). R-2EC is 5 or 1, 1 or 8, and 15 (10). R-3 is 8 or 1, 1 or 8, and 20 (20). R-3EC is 5 or 1, 1 or 6, and 15 (10). R-4 is 8 or 1, 1 or 6, and 15 (10). R-5 is 8 or 1, 1 or 6, and 15 (10). R-9 is 5 or 1, 1 or 5, and 10.
The 1-foot side option generally requires the building to sit at least 6 feet behind the house, or 4 feet in R-2EC. In R-1-10, R-1-8, and R-1-6 it also requires 60 feet from the front lot line, plus 6 to 10 feet from an adjacent dwelling depending on the zone. No detached accessory building may sit between the front of the house and the street. On a lot over half an acre, a building larger than 80 percent of the house footprint must meet the main building’s side and rear setbacks.
Parking is the house’s two existing off-street spaces. The ADU uses tandem parking in the driveway. No added front-yard or side-yard parking pad is allowed.
The owner must occupy either unit. A seasonal absence of up to 4 months is allowed, and the vacant unit may not be rented during that time. The non-owner unit is limited to 2 adults plus minor children.
In an R-1 zone, a short-term rental of less than 30 days is allowed only if the property is owner-occupied, and not in an ADU unless one unit is owner-occupied (15-13-38).
An accessory dwelling permit is required. It is void on sale, and a certificate is recorded.
The 2026 Planning Fee Update, effective July 1, 2026, lists the ADU land-use application at $288.87. Building permit fees are separate. 2026 Ogden ADU application
Not yet verified
- The Zone Ogden code update, including a 6,000 square foot lot minimum, is proposed only and unscheduled. It is not current law.